Annex 5. Technical Requirements for Protective Structures (Elements)

Technical requirements for protective structures and elements of shooting ranges for practical shooting.

Annex 5. Technical requirements for protective structures (elements)

to the Official Rules
for practical shooting sport competitions

Technical requirements for protective structures (elements) of semi-open shooting ranges (shooting ranges) for practical shooting

Table 1

Height of protective structures (elements) for firing a carbine and a smoothbore shotgun

Shooting distance, m Minimum height H, m
Up to 25 3,00
from 25including to 50 4,00
from 50 including to 100 6,00
from 100 including to 200 7,5
from 200 including to 300 10,00

Table 2

Height of protective constructions (elements) for shooting of the handgun, carbine under the handgun cartridge, small-caliber carbine

Shooting distance, m Minimum height H, m
Up to 15 3,00
From 15 including to25 4,00
From 25 including to 50 5,00
over 50 6,00

Table 3

Requirements for the design of protective structures (elements), depending on the type of firearm and caliber of ammunition

Thickness of protective structures (elements), cm, by type and caliber of ammunition and type of firearm

Material Carbine from 7.62x54 to 12.7 × 99 mm NATO carbine 7.62x39 carbine 5,45х39 and 5,56х45 (cal.223) carbine 5,6mm (cal.22) handgun and carbine for handgun cartridge, all calibers smoothbore shotgun, up to 12 caliber inclusive, fraction smoothbore shotgun, up to 12 caliber inclusive, canister smoothbore shotgun, up to 12 caliber inclusive, bullet
Concrete brands 350 (В25) 30 8 8 7 7 7 7 15
Brick М100 80 38 38 25 25 25 25 25
Wood 100 50 50 25 10 5 10 15
Maul*) 100 80 80 50 20 20 20 20
Sand (compacted) **) 100 60 60 30 10 10 10 20
Vegetable soil *) 120 80 80 50 30 20 20 50

*) Used in embankments. The given thickness applies to the upper edge of the shaft.

**) Thickness for layered material filled between two wooden walls 5 cm thick.